Description
Summary:
This Acceleration Mechanical Shock Test System has advanced design, reliable work, convenient operation and reasonable price. It is an environmental test equipment for evaluating the reliability and structural integrity of the test piece after being impacted.
It has fully digests and absorbs the advantages of the impact test benches of MTS and Yoshida Seiki of Japan. The appearance is more refined and beautiful, the vibration damping device is more scientific, and the work reliability is high. It is suitable for aviation, aerospace, shipbuilding, Products in the ordnance, electronics, automobiles, home appliances and transportation industries provide test equipment for the impact resistance of their products
Standards:
GB T2423.5 / IEC 60068-2-27: Environmental testing — Part 2: Test Methods — Test Ea and Guidance: Shock
GJB150.18: Environmental test methods for military equipments: Shock test
IEC68-2-29: Test Eb and guidance:Bump
JJG497-2000: Verification Regulation of Bump Testing Machines
JESD22-B111: Board Level Drop Test Method of Components for Handheld Electronic Products
ETC
Advantage:
※ Digital setting of impact height: The impact table is automatically raised to the set height, with high control accuracy and good repeatability of impact data.
※ Waveform generator can be optional: half-sine wave generator is standard configuration, trapezoidal wave, rear peak sawtooth wave generator can be configured.
※ The impact table adopts centrifugal casting process, the trunnion and the work table are integrated, and the impact energy transfer ratio is maintained at 1:1.
※ The precision acquisition system adopts photoelectric displacement sensor, which has high precision of table top and good repeatability of impact index.
Main Parameters:
Impact Test Machine | |
Maximum load | 10kg |
Table test size | 200mm×220mm |
Pulse Duration time | 1ms~20ms |
Acceleration range | 15~1000g |
Waveform | Sinusoidal half-wave |
Impact Control Measurement Analyzer | |
Input channel | |
Input channel | 1 charge input channel |
Sampling frequency | Max 192kHz |
Coupling method | Built-in charge amplifier |
Pulse width | 0.5 ms~1000ms |
Acceleration range | 10000g |
Support standard | IEC;GJB150;GJB360;GB2423;MIL-STD-810 etc |
Output channel | |
Output channel | 1 charge output channel |
Voltage range | ±10V |
Electrical parameters | |
Power Supply | AC 100~240V |
Power | 20W |
Communication Interface | USB2.0 |
Operation System | Windows XP |
Environmental parameters | |
Temperature and humidity | 0 to 45°C; 10% to 90%RH, without condensation |
Reviews